Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 454-459, 2022.
Article in Chinese | WPRIM | ID: wpr-958428

ABSTRACT

Objective:To summarize the clinical data of mitral valve surgery completed in a single surgical team in one year, to discuss the etiologic characteristics, methods, results and early postoperative outcomes of mitral valvuloplasty surgeries, and to analyze the epidemiologic trends of mitral valve diseases admitted to the hospital.Methods:A total of 209 mitral valve surgeries completed by the same surgeon in the single surgical team at the Cardiovascular Surgery, First Medical Center, Chinese PLA General Hospital, from January 2021 to December 2021 were retrospectively analyzed. Mitral valve surgery accounted for 53.6% of all surgeries in this team during the same period. There were 100 cases(47.8%) in males and 109 cases(52.2%) in females, aged 11-85 years old, with a mean of(53.5±15.2) years old. There were 121 cases(57.9%) of NYHA class Ⅱ and 88 cases(42.1%) of class Ⅲ/Ⅳ.Results:Of the 152 mitral valvuloplasty surgeries, 117(77%) were performed with a totally Thoracoscopic approach. Annuloplasty rings were applied in 145 cases(95.4%), including semi-rigid closed Physio II annuloplasty rings in 118 cases(81.4%), Gore-Tex artificial chordae were applied in 89 cases(58.6%) for a total of 145, leaflet repair in 15 cases(9.9%), edge-to-edge repair in 2 cases(1.3%), commissure suture in 34 cases(22.4%), and chordae tendineae and papillary muscle splitting in 15 cases(9.9%). The repair rate of degenerative mitral valve disease was 100%, and the repair rate of rheumatic mitral valve disease was 48.1%. The echocardiogram was received about one week after surgery, and there was no or trace regurgitation in 91 cases(59.9%), mild in 58 cases(38.2%), and moderate in 3 cases(2.0%). There were 2 cases(1.3%) of all-cause death.Conclusion:Degenerative mitral valve disease have become the leading cause of mitral valve disease in our center, and the proportion of rheumatic mitral valve disease has decreased. Degenerative mitral valve disease has a very high repair rate, and rheumatic mitral valve disease has a relatively low repair rate due to its special pathologic and anatomic characteristics. Most mitral valvuloplasty procedure can be performed in a totally thoracoscopic approach. The application of a mitral valvuloplasty ring combined with Gore-Tex artificial chordae by an experienced surgeon can achieve reliable repair results.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 845-850, 2020.
Article in Chinese | WPRIM | ID: wpr-823436

ABSTRACT

@#Mitral valvuloplasty is a more suitable surgical procedure than mitral valve replacement in the case of mitral valve degeneration. Quadrangular resection and artificial chordae plantation, considered to be classical procedures, are widely employed in posterior mitral valve prolapse, and have prominent long-term effects during the follow-up. However, is there any difference in mitral valve reconstruction due to completely different surgical methodology and concepts of the two procedures? Every surgeon has his own ideas and preferences for mitral valvuloplasty, and the choice of surgical procedures mostly depends on experience of surgeons. The article generally reviews variances in intraoperative and long-term clinical outcomes of both rectangular excision and artificial chordae plantation in posterior leaflet valvuloplasty, hoping to provide references for clinical decision.

3.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 759-765, 2019.
Article in Chinese | WPRIM | ID: wpr-750298

ABSTRACT

@#Objective    To analyze the effect of loop-in-loop technique and annuloplasty ring for the treatment of mitral valve prolapse (MVP) under total thoracoscopy. Methods    Between May 2012 and May 2017, 21 patients with MVP underwent mitral valve repair in our hospital. There were 12 males and 9 females with a mean age of 50.90±9.66 years and the mean weight of 64.81±11.56 kg. Loop-in-loop artificial chordae tendonae reconstruction and mitral annuloplasty were performed through the right atrial-atrial septal incision under total thoracoscopy. The water test and transesophageal echocardiography were performed during the operation to evaluate the effect of mitral annuloplasty. Data of echocardiography and chest radiography were collected postoperatively one week, before discharge and after discharge. Results    All the operations were successful without re-valvupoplasty or valve replacement, conversion to median thoracotomy, malignant arrhythmia, perioperative death or wound infection. Among them, 10 patients underwent tricuspid valvuloplasty, 1 patient underwent tricuspid valvuloplasty plus radiofrequency ablation simultaneously. The mean cardiopulmonary bypass time was 255.57±37.24 minutes, aortic occlusion time was 162.24±19.61 minutes, the number of loop was 2–5 (3.29±0.78), the size of ring was 28–34 (31.11±1.88) mm, ventilator assistance time was 19.43±14.68 hours, ICU time was 58.45±24.60 hours and postoperative hospital stay was 12.28±3.61 days. Transthoracic echocardiography was re-examined postoperatively. Mild-mitral regurgitation was found in 3 patients. Warfarin anticoagulant therapy was given orally for 6 months postoperatively. The patients were followed up regularly for 2–51 months at 1, 3, 6 and 12 months postoperatively. Left ventricular end-diastolic diameter (LVEDD) was 45.06±2.96 mm, left ventricular end-diastolic volume 108.11±17.09 mL, left atrial diameter (LAD) 35.56±6.93 mm and cardiothoracic ratio 0.53±0.13 at discharge which were significantly smaller than those at admission (P<0.05). Pulmonary artery pressure was 19.22±6.38 mm Hg which was significantly lower than that at admission (P<0.05), but left ventricular ejection fraction (62.33%±4.00%) had no significant change (P>0.05). The LAD and LVEDD were significantly smaller than those before operation, and the cardiac function improved to some extent during the follow-up. No new mitral valve prolapse, increased regurgitation, infective endocarditis, thromboembolism or anticoagulation-related complications were found during the follow-up. Conclusion    Loop-in-loop artificial chordae tendon implantation combined with mitral annuloplasty is a safe and effective method for MVP under total thoracoscopy with minimal trauma, satisfactory cosmetic effect, and good early- and medium-term results. It is worth of popularizing. However, the operation time needs to be further shortened, and its long-term clinical effect needs further follow-up and other researches to confirm.

4.
Japanese Journal of Cardiovascular Surgery ; : 324-326, 2019.
Article in Japanese | WPRIM | ID: wpr-758249

ABSTRACT

A 34-year-old man was referred to our hospital for primary tricuspid regurgitation. An echocardiogram showed severe tricuspid regurgitation caused by the prolapse of the anterior leaflet due to chordal rupture and enlargement of the tricuspid annulus. A large cleft on the anterior leaflet and a divided leaflet near the septal leaflet with a ruptured chorda were observed during surgery. We attached an artificial chorda from the anterior papillary muscle of the right ventricle to the prolapsed leaflet. We then repaired the large cleft with interrupted 6-0 polypropylene sutures and performed tricuspid annuloplasty. The prolapse of the anterior leaflet disappeared, and an intraoperative transesophageal echocardiogram revealed improvement of tricuspid regurgitation. The technique of mitral valve repair can be used even for a complex pathology of congenital cleft, chordal rupture, and annular enlargement of the tricuspid valve.

5.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 787-790, 2017.
Article in Chinese | WPRIM | ID: wpr-750329

ABSTRACT

@#Objective    To evaluate the outcomes and summarize the clinical experience of totally endoscopic mitral valve repair with artificial chordae implantation. Methods    From May 2013 to June 2016, 71 patients with mitral valve insufficiency were admitted to our hospital who underwent totally endoscopic mitral valve repair with artificial chordae implantation. There were 47 males and 24 females with the age of 46.0±14.4 years ranging from 13-78 years. The pathogenesis included degenerative valvular diseases in 63 patients, congenital valvular diseases in 4, infectious endocarditis in 2, rheumatic disease in 1 and cardiomyopathy in 1. Prolapse of anterior, posterior, or both leaflets was present in 26 (36.6%), 19 (26.8%), and 25 (35.2%) patients, respectively; one patient (1.4%) presented valve annulus enlargement and thirteen were associated with commissure lesion. The mitral regurgitation area ranged from 4.2 to 26.3 cm2 (mean, 12.2±5.6 cm2). All the procedures were performed by total endoscopy under cardiac arrest. 5-0 Gore-tex sutures were used as the material of artificial chordae which was implanted one by one. Results    There was no in-hospital death. One patient was transferred to mitral valve replacement, and one median sternotomy due to bleeding. The mean cardiopulmonary bypass time was 156.0±31.6 min and aortic cross-clamp time 110.0±20.1 min. We finally had 39 isolated mitral valve repair, 28 mitral valve repair combined tricuspid valve repair, 3 mitral valve repair combined atrial septal  defect closure, and 1 mitral valve repair combined correction of partial anomalous pulmonary vein connection. Each patient was implanted artificial chordae of 2.5±1.7 (ranging from 1 to 7), and 65 patients received mitral annulus (full ring). The intraoperative transoesophageal echocardiography found no mitral regurgitation in 44 patients, the area of mitral regurgitation was 0-2 cm2 in 24, and 3 patients with mitral regurgitation>2 cm2 experienced serious systolic anterior motion. Of the 3 patients with systolic anterior motion (SAM), one transferred to mitral valve replacement, one underwent mitral re-repair, and one took conservative treatment. The mean follow-up was 12.7±10.5 months (range: 1 to 36 months), while 2 patients were lost to follow up with the follow-up rate of 97.2%. Recurrent severe regurgitation occured in 3 patients, moderate in 5, mild or trivial in 27 and no regurgitation in 36. During the follow-up, 1 patient died of myocardiopathy-induced heart failure post discharge, 1 suffered from cerebral infarction, and no patient underwent reoperation. Conclusion    The totally endoscopic surgical treatment of mitral valvuloplasty with artificial chordae is reliable for patients with mitral valve prolapse, which provides favorable clinical efficacy and outcomes. The difficulty lies in how to determine the appropriate length of the chordae and keep the stability of length.

6.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 979-982, 2017.
Article in Chinese | WPRIM | ID: wpr-749851

ABSTRACT

@#Objective    To evaluate the mid-long term results of application research of artificial Gore-Tex chordate in mitral valvuloplasty in patients with mitral insufficiency caused by endocarditis. Methods    We retrospectively analyzed the clinical data of 28 consecutive infective endocarditis(IE) patients who received mitral valve repair with Gore-Tex in our hospital between January 2012 and December 2015. There were 17 males and 11 females. The age of these patients ranged from 18 to 69 (52.0±15.4) years. Echocardiography before operation showed the degree of mitral regurgitation (MR) was severe in 19 patients, moderate in 9 patients. Six patients were in New York Heart Association (NYHA) class Ⅱ, 14 in class Ⅲ, 8 in class Ⅳ. There were 26 selective surgeries and 2 emergent surgeries. One patient had concomitant coronary artery bypass graft. Six patients had aortic valve replacement. Five patients had aortic valve repair. Twenty patients had tricuspid valve repair. Five patients had Maze procedure. Results    Follow-up was done to all the patients for 6 months to 55 (30.5±6.4) months. During the follow-up, the echocardiography showed that postoperative left atrium diameter (36.64±8.50 mm vs. 51.78±17.50 mm, P<0.05) and left ventricular end-diastolic dimension (49.30±5.05 mm vs. 57.70±7.49 mm, P<0.05) were significantly smaller than those before operation. The left ventricular ejection fraction (EF) increased from 53.86%±8.16% to 59.14%±4.23% (P<0.05). No MR was found in 16 patients, mild MR in 8 patients, mild to moderate MR in 2 patients, moderate MR in 1 patient. One patient required reoperation for   recurrent infection. No death or complications related to thrombosis and embolism occurred after operation. Conclusion    Application research of artificial Gore-Tex chordate in mitral valve repair is feasible for treating mitral valve lesions caused by endocarditis, and may provide a long-term outcome to the patients.

SELECTION OF CITATIONS
SEARCH DETAIL